GB15
1. Control panel.
2. Grease filter.
3. Lighting
4. Extractor unit body.
DESCRIPTION AND USE OF HOOD
q
w
r
e
Operation
Use the high suction speed in cases of concentrated kitchen vapours. It is
recommended that the cooker hood suction is switched on for 5 minutes prior
to cooking and to leave in operation during cooking and for another 15
minutes approximately after terminating cooking.
1 ON/OFF motor
Pressing the button, the hood turns on at speed 1.
Pressing the button during functioning, the hood turns OFF.
2 Speed Increase
Pressing the button the hood passes from the OFF state to speed 1.
Pressing the button (hood in ON state) the motor speed is increased
from speed 1 to intensive.
To each speed corresponds the ignition of the respective led.
Speed 1 led L1
Speed 2 led L2
Speed 3 led L3
Intensive Speed led L4 (flashing)
The intensive speed is timed. The standard timing is 5’, at the end of
which the hood positions itself to speed 2.
To deactivate the function before the time expires press key 2, the hood
positions itself to speed 1, pressing key 1 the hood will turn off.
3 ON/OFF lights
4 Speed timing
5 Function state indicator
Speed Timing
The timing of the speed is enabled by pressing key 4, once the timing expires
the hood turns off.
The timing is subdivided as follows:
Speed 1 - 20 minutes (led L1 flashing)
Speed 2 - 15 minutes (led L2 flashing)
Speed 3 - 10 minutes (led L3 flashing)
Intensive Speed - 5 minutes (led L4 flashing)
During the timed functioning pressing key 1 the hood turns off, if you press
key 2 or key 4 the hood returns to the set speed.
Grease trap Signal
After 40 hours of operation the led L5 turns on.
When such signal appears the installed grease trap needs to be washed.
To reset the signal hold down key 1 for 3”.
Carbon filter Signal
After 160 hours of operation the led L5 flashes.
When such signal appears the installed carbon filter must be substituted.
To reset the signal hold down key 1 for 3”.
In the case of both filters signalling at the same time, the led L5 will indicate
the alarms alternately remaining on for 3" and subsequently flashing 3 times.
The reset takes place by carrying out the procedure described above 2 times.
The first time resets the grease trap signal, the second resets the carbon filter
signal.
In the standard mode the carbon filter signal is not active.
In case one uses the hood in filter version is it necessary to enable the carbon
filter signal.
Carbon filter signal activation:
Position the hood in OFF and simultaneously hold down keys 1 and 4 for 3”.
The led L1 and L2 will flash for 5”.
Carbon filter signal deactivation:
12 5