WHAT TO DO IF...
If fault occurs, before contacting the After-sales Service, make the following checks to try and remedy the problem. Most
faults can be remedied by taking the following action, quickly restoring normal appliance operation.
The appliance... Possible causes... Solutions...
Display shows:
CHECK SALT or
REFILL SALT
Salt reservoir is empty. Refill reservoir with salt (see page 4).
Adjust water hardness (see page 4).
Display shows:
CHECK RINSE AID or
REFILL RINSE AID
Rinse aid dispenser is empty. Refill dispenser with rinse aid (see page 5).
... is not working/will not start. The appliance must be switched on. Check the household circuit fuse if there is no power
supply.
The appliance door doesn’t close. Check if the appliance door is closed.
“Delay” option is ON. Check whether the "Delay" option has been
selected. If it has, the appliance will start once the
set time has elapsed. If necessary, RESET the
appliance by pressing or start the cycle
immediately by pressing .
Display shows:
NO WATER!
CHECK CONNECTION
MORE INFORMAITON
IS AVAILABLE IN
THE INSTRUCTIONS
(CODE F6-E1)
Water tap closed. The water tap must be open.
Water pressure is too low. The water tap must be fully open during water inlet
(minimum capacity: 0.5 litres per minute).
Kinked water inlet hose or closed inlet filters. The water inlet hose must not be kinked and the
relative inlet filter in the water tap connector must
not be dirty or clogged.
Display shows:
CYCLE STOPPED
CHECK DRAIN HOSE
MORE INFORMAITON
IS AVAILABLE IN
THE INSTRUCTIONS
(CODE F8-E1)
Dirty filters. Clean the filters.
Kinked drain hose. The drain hose must not be kinked.
Syphon hose connection closed. The closure disk of the syphon hose connection
must be removed.
Display shows:
CYCLE STOPPED
CHECK FILTER
MORE INFORMAITON IS
AVAILABLE IN
THE INSTRUCTIONS
(CODE F6-E3)
Dirty filters or spray arms. Clean filters and spray arms.
Too little water in the appliance system. Concave items (e.g. bowls, cups) must be arranged
facing downwards in the rack.
Drain hose incorrectly fitted. The drain hose must be fitted correctly (for high
mounted appliances, leave min. 200 - 400mm from
the lower edge of the appliance) - see Assembly
Instruction.
High level of foam inside. Repeat without detergent or wait until foam
disappears.
Display shows:
PRESS fflst AND
CLOSE THE DOOR
Door is not closed with in 3 seconds of button
press.
Press again and close the appliance door
within 3 seconds.
Display shows:
OPEN AND CLOSE
THE DOOR
The door was not open between cycles. Unload appliance (if not unloaded before), open
and close the door.
Display shows:
CLOSE WATER NOW
CALL THE SERVICE
MORE INFORMATION IS
AVAILABLE IN
THE INSTRUCTIONS
(CODE F8-E1) or
Display shows other fault display: Fx-Ey
Appliance has technical defect. Call factor customer service (state fault displayed).
Close the water tap.
After taking the above action, the fault message must be reset. In the majority of cases the fault is thus eliminated.
RESET:
- Press the button for 3 seconds;
- Close the door;
- Water drains automatically for up to 1 minute;
- The appliance is now ready to be started.