Dishwasher must be level for proper dish rack operation and wash performance.
1. Place a spirit level on door and rack track inside the tub as shown to check that the dishwasher is level.
2. Level the dishwasher by adjusting the three levelling legs individually.
3. When level the dishwasher, please pay attention not to let the dishwasher tip over.
Figure 8
Illustration of feet adjustment.
NOTE: The maximum adjustment height of the feet is 50 mm.
Check level
fron to back
Check level side to side
About electricity connecting
For personal safety:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE EARTHING
CONNECTION FROM THE POWER CORD.
Electrical requirements
Please look at the rating label to know the rating voltage and connect the dishwasher to the appropriate
power supply. Use the required fuse 10 amp, time delay fuse or circuit breaker recommended and
provide separate circuit serving only this appliance.
Insure proper ground exists before use
Electrical connection
Ensure the voltage and frequency of the power being corresponds to those on the rating plate. Only insert
the plug into an electrical socket which is earthed properly. If the electrical socket to which the appliance
must be connected is not appropriate for the plug, replace the socket, rather than using a adaptors or the
like as they could cause overheating and burns.
Groundig instruction
This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk
of electric shock by providing a path of least resistance for the electric current. This appliance is equipped
with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into
an appropriate outlet that is installed and earthed in accordance with all local standards and requirements.
WARNING: